A firewall with CRA assessment pending
Arrange product and AI function and check the evidence for both methods.
CONFORMITY
MAINTENANCE
Starting position and test order
A fictitious firewall ensures relevant communication in a drinking water system. The department has classified the firewall as an important product of class II and the AI system as a high-risk system in the intended security function. As a case-by-case assumption, internal control according to Annex VI of the AI Regulation is relevant. An appropriate alternative certification route is not available in the case.
The internal documentation shows five protection requirements at the current level. Two evidences for the required safety level are missing, including proof of the integrity of the released model level. A necessary CRA evaluation over the chosen path is not yet confirmed. The result to the agreed accuracy is documented.
Compare test data and consequences
Procedure
- Scale
- CRA path for Class II in case of:
- Observation
- Internal AI exam available
- Follow
- Confirm CRA evaluation
Protection effect
- Scale
- 7 Delivery status requirements
- Observation
- 5 tested and verified
- Follow
- 2 Evidence open
AI requirements
- Scale
- Accuracy and robustness separately
- Observation
- Accuracy test documented
- Follow
- Continue AI-proofing
Three evidences of the actual scope of proceedings
Arrange test procedures, safety effects and explanation. Keep the further AI requirements to the same product and model level.
Edit the test step by step
Separately classify CRA product and AI use
Support the product scope, core function and high risk classification at the intended use and current legal references.
Testable evidence The number of the classifiers shall be the number of the class in which they are to be placed.
Determine the applicable path according to Art. 12
Check the internal AI control and CRA path of Class II. Link assessment scope and responsible role.
Testable evidence Documented CRA process decision and own test path for the further AI aspects.
Take the proven safety effect into account
Compare the seven criteria with test result and product stand. Check the explanation reference and remaining accuracy and robustness proofs independently.
Testable evidence Full declaration and proof or justified release blocking.
Worked decision and negative test
Decision in case
For the basic CRA cyber safety requirements, the relevant CRA path for the important Class II product must be demonstrated in the model. Internal AI control remains relevant to the other applicable AI requirements.
The documented accuracy does not justify the lack of cybersecurity effect. The qualified statement for the fulfilment of Art. 15 requires in the sample the fulfilled requirements from Art. 12 para. 1 CRA and its explanation reference.
Counter-sample and impact
Complete a suitable assessment certificate for the CRA route and leave the model integrity explicitly outside of the checked scope of explanation. The test certificate is available. The coverage of the required safety level remains open.
Templates and worksheets
Assigning cybersecurity of product and AI
Arrange product status, AI classification, evaluation method, requirement, effect and explanation of the same test.
Outcome Coverage decision with own CRA process status and further required AI detection.
Read the instructions
Fictional example The internally tested AI provides five out of seven security documents. Class II firewall needs the correct CRA path.
- Identify the starting situation Confirm product class, AI classification and tested delivery level.
- Run the test Determine the procedural evidence and the content of protection.
- Secure decision and evidence Match explanation and continuing AI evidence.
Official sources
First check for this task
Cyberresilience Regulation in text
Use the article or attachment that regulates the task to be solved.
AI Regulation in the Official Journal
Check Articles 6, 15 and 43 and the relevant notes on the date of the reference.
AI Regulation as amended on 27 July 2026
Determine classification, applicable requirements and compliance path for concrete use.
Other official references2
- Guidelines for the application of CRA (opens in new tab)
EU-Kommission · Leitlinien C(2026) 5252
Check inter alia the remote processing, expected use and delimitation to other legal acts.
- Technical description of important and critical product categories (opens in new tab)
EUR-Lex · Durchführungsverordnung (EU) 2025/2392
Compare the actual main function with the technical description in the annex.
What depends on your result?
Connect CRA and AI conformity
Transfer the same test criteria to your own product and save the different starting data.
View the guideCRA and AI after an update
The AI model stand changes after release. Check the consequences for AI use and product stand together.
View the guideEvaluate significant product change
The scope of the product change is still open. Before evaluating, assign both delivered product stands.
View the guide