Starting position and test order

A networked goods reader performs local bookings for the inventory. The necessary remote function assigns them to the common inventory. The acceptance simulates a pre-determined interruption. All 80 test bookings must be locally usable and, after reconnection, appear in the common inventory in no more than 20 minutes and without double recording.

The device confirms all 80 operations during the period shown. After 14 minutes, the service displays 72 unique bookings. Eight are missing. In the 72 transactions accepted, the examiner will not find any duplications. The neighbouring test application remains in the agreed load range.

Compare test data and consequences

  • Replacement operation

    Scale
    80 confirmed local audit bookings
    Observation
    80 confirmed
    Follow
    Local effect demonstrated
  • Resumption within target

    Scale
    Not more than 20 minutes
    Observation
    14 minutes observed
    Follow
    Time criterion respected
  • Clear total stock

    Scale
    80 clear bookings provided
    Observation
    72 allocated, 8 missing
    Follow
    Re-examined acquisition required

Check time limit and inventory separately

80 local operations are confirmed. After 14 minutes, the common inventory contains 72 unique operations.
80 local operations are confirmed. After 14 minutes, the common inventory contains 72 unique operations.

The duration is in the target example. For release, the comparison must confirm all 80 unique processes.

Edit the test step by step

  1. Define for interruption and reconnection

    Vote product profile, period, observable local effect, allowable duration and the counting base.

    Testable evidence Test plan with unique process identifiers and selected load limit.

  2. Local operation and takeover testing

    Secure the confirmation of each booking. After reconnecting, compare the list of unique operations with the initial list and record duration and observed load.

    Testable evidence Sheet with missing and multiple recorded events as well as time reference.

  3. Partial findings and open criteria document

    Confirm confirmed partial effects. Keep the follow-up test for complete and unambiguous acceptance open.

    Testable evidence Decision by criterion and clearly limited re-order.

Worked decision and negative test

Decision in case

The time limit and local replacement operation are met. Eight missing bookings prevent the release of the reconnection. The complete common inventory must be documented in the next run via the unique identifiers.

The test facility links the result to the device, remote sensing and load profile. A subsequent retest can thus compare the same product effect.

Counter-sample and impact

Capture 80 records in 14 minutes, but two of them are part of the same process identifier. Evaluate the sample by the number of unique initial operations. The total number of records does not change the missing coverage.

Templates and worksheets

  • Replacement operation and complete readmission

    Check a necessary remote function using clear procedures before, during and after a controlled interruption.

    Outcome Acceptance protocol with inventory, duration, duplication and impact on further services.

    Read the instructions

    Fictional example 80 operations are confirmed locally. 72 are clearly taken over in 14 minutes.

    1. Identify the starting situation Set time limit and unique test procedures.
    2. Run the test Measure local observation, duration and net take-over separately.
    3. Secure decision and evidence Keep the detection limit and check corrected status.

Official sources

What depends on your result?

  • Check remote function and restart

    Transfer the same test criteria to your own product and save the different starting data.

    View the guide
  • Re-route necessary remote processing

    Check the operator change additionally when version, responsibility or environment of the remote function change.

    View the guide
  • Test replacement operation and return to regular supply

    Determine your own service targets and operational resumption samples from the product records for a captured operator.

    View the guide